SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R09

13Packet switched data services
Page 127 of 307
Parameter Type Description
o 2: disable
• 37: 3G minimum QoS erroneous SDU delivery - <param_val> selects the acceptable
value for the erroneous SDU delivery:
o 0 (factory-programmed value): subscribed
o 1: no detection
o 2: enable
o 3: disable
• 38: 3G minimum QoS extended guaranteed downlink bit rate - <param_val> is
the value for the extended guaranteed downlink bit rate in kb/s. The factory-
programmed value is 0.
• 39: 3G minimum QoS extended maximum downlink bit rate - <param_val> is the
value for the extended maximum downlink bit rate in kb/s. The factory-programmed
value is 0.
• 40: 3G minimum QoS guaranteed downlink bit rate - <param_val> is the value for
the guaranteed downlink bit rate in kb/s. The factory-programmed value is 0.
• 41: 3G minimum QoS guaranteed uplink bit rate - <param_val> is the value for the
guaranteed uplink bit rate in kb/s. The factory-programmed value is 0.
• 42: 3G minimum QoS maximum downlink bit rate - <param_val> is the value for the
maximum downlink bit rate in kb/s. The factory-programmed value is 0.
• 43: 3G minimum QoS maximum uplink bit rate - <param_val> is the value for the
maximum uplink bit rate in kb/s. The factory-programmed value is 0.
• 44: 3G minimum QoS maximum SDU size - <param_val> is the value for the
maximum SDU size in octets. The factory-programmed value is 0.
• 45: 3G minimum QoS residual bit error rate - <param_val> selects the acceptable
value for the residual bit error rate:
o 0 (factory-programmed value): subscribed
o 1: 5E2
o 2: 1E2
o 3: 5E3
o 4: 4E3
o 5: 1E3
o 6: 1E4
o 7: 1E5
o 8: 1E6
o 9: 6E8
• 46: 3G minimum QoS SDU error ratio - <param_val> selects the acceptable value
for the SDU error ratio:
o 0 (factory-programmed value): subscribed
o 1: 1E2
o 2: 7E3
o 3: 1E3
o 4: 1E4
o 5: 1E5
o 6: 1E6
o 7: 1E1
• 47: 3G minimum QoS signalling indicator - <param_val> selects the acceptable
value for the signalling indicator:
o 0 (factory-programmed value): subscribed
o 1: signalling indicator 1
• 48: 3G minimum QoS source statistics descriptor - <param_val> selects the
acceptable value for the source statistics descriptor:
o 0 (factory-programmed value): subscribed
o 1: source statistics descriptor 1
• 49: 3G minimum QoS traffic class - <param_val> selects the acceptable value for
the traffic class:
o 0 (factory-programmed value): subscribed
o 1: conversational
o 2: streaming
o 3: interactive
o 4: background

Table of Contents

Other manuals for Ublox SARA-R4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ublox SARA-R4 Series and is the answer not in the manual?

Ublox SARA-R4 Series Specifications

General IconGeneral
BrandUblox
ModelSARA-R4 Series
CategoryControl Unit
LanguageEnglish

Related product manuals