SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R09

19SSL/TLS
Page 208 of 307
Parameter Type Description
o 0 (factory-programmed value): (0x0000) Automatic the cipher suite will be negotiated in
the handshake process
o 1: (0x002f) TLS_RSA_WITH_AES_128_CBC_SHA
o 2: (0x003C) TLS_RSA_WITH_AES_128_CBC_SHA256
o 3: (0x0035) TLS_RSA_WITH_AES_256_CBC_SHA
o 4: (0x003D) TLS_RSA_WITH_AES_256_CBC_SHA256
o 5: (0x000a) TLS_RSA_WITH_3DES_EDE_CBC_SHA
o 6: (0x008c) TLS_PSK_WITH_AES_128_CBC_SHA
o 7: (0x008d) TLS_PSK_WITH_AES_256_CBC_SHA
o 8: (0x008b) TLS_PSK_WITH_3DES_EDE_CBC_SHA
o 9: (0x0094) TLS_RSA_PSK_WITH_AES_128_CBC_SHA
o 10: (0x0095) TLS_RSA_PSK_WITH_AES_256_CBC_SHA
o 11: (0x0093) TLS_RSA_PSK_WITH_3DES_EDE_CBC_SHA
o 12: (0x00ae) TLS_PSK_WITH_AES_128_CBC_SHA256
o 13: (0x00af) TLS_PSK_WITH_AES_256_CBC_SHA384
o 14: (0x00b6) TLS_RSA_PSK_WITH_AES_128_CBC_SHA256
o 15: (0x00b7) TLS_RSA_PSK_WITH_AES_256_CBC_SHA384
• 3: trusted root certificate internal name;
o <param_val> (string) is the internal name identifying a trusted root certificate; the
maximum length is 200 characters. The factory programmed value is an empty string.
• 4: expected server hostname;
o <param_val> (string) is the hostname of the server, used when certificate validation level
is set to Level 2; the maximum length is 256 characters. The factory programmed value is
an empty string.
• 5: client certificate internal name;
o <param_val> (string) is the internal name identifying a client certificate to be sent to the
server; the maximum length is 200 characters. The factory programmed value is an empty
string.
• 6: client private key internal name;
o <param_val> (string) is the internal name identifying a private key to be used; the
maximum length is 200 characters. The factory programmed value is an empty string.
• 7: client private key password;
o <param_val> (string) is the password for the client private key if it is password protected;
the maximum length is 128 characters. The factory programmed value is an empty string.
• 8: pre-shared key;
o <param_val> (string) is the pre-shared key used for connection; the maximum length is 64
characters. The factory programmed value is an empty string.
• 9: pre-shared key name;
o <param_val> (string) is the pre-shared key name used for connection; the maximum length
is 128 characters. The factory programmed value is an empty string.
• 10: SNI (Server Name Indication);
o <param_val> (string) value for the additional negotiation header SNI (Server Name
Indication) used in SSL/TLS connection negotiation; the maximum length is 128
characters. The factory programmed value is an empty string.

Table of Contents

Other manuals for Ublox SARA-R4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ublox SARA-R4 Series and is the answer not in the manual?

Ublox SARA-R4 Series Specifications

General IconGeneral
BrandUblox
ModelSARA-R4 Series
CategoryControl Unit
LanguageEnglish

Related product manuals