10.3.3î™–î™–î™–î™–Defined values
Parameter Type Description
<value> Number
• 0: the DCE ignores circuit 108/2
• 1 (default value and factory-programmed value): upon an ON-to-OFF transition of
circuit 108/2, the DCE enters online command state and issues an OK result code
• 2: upon an ON-to-OFF transition of circuit 108/2, the DCE performs an orderly
cleardown of the call. The automatic answer is disabled while circuit 108/2 remains
OFF
10.3.4î™–î™–î™–î™–~+++ behavior in PSD &D
SARA-R4 / SARA-N4
The ~+++ behavior in PSD &D is not supported.
• A special meaning of the &D value is provided for the ~+++ sequence during a PSD data transfer with PPP
L2 protocol (this is outside the V25-ter specification scope). The ~+++ causes context deactivation during
a PSD data transfer session for the AT&D0 and AT&D2 value (the +++ return to on-line command mode is
provided for each &D value during a CSD data call)
• A different implementation for the ~+++ is done with the &D1 value: the PSD data transfer is escaped and
system returns in the on-line command state. The ATO command is used to resume the PSD data transfer
session
• During the on-line command mode different AT commands can be sent but data calls in PSD on-line
command mode cannot be granted (activate the AT+CRC=1 mode to identify the kind of call and reject data
incoming calls if PSD is in the on-line command mode)
For more details see the ITU-T Recommendation V250 [20], ITU-T V.25ter Recommendation [21] and
ITU-T V.32 Recommendation [22].
See the corresponding module system integration manual for the DTR behavior during the initialization
phase of the module.
10.3.5î™–î™–î™–î™–Circuit 108/2, +++ behavior for the different &D: summarizing tables
CSD data mode
Event DTE sends escape sequence (e.g. +++) DTR On to Off transition
&D0 DCE enters command mode No action
&D1 DCE enters command mode Switch to command mode
&D2 DCE enters command mode Cleardown call
Table 6: CSD data mode
PSD data mode (PPP L2 protocol case)
Event DTE sends ~+++ DTR On to Off transition
&D0 Context deactivation No action
&D1 DCE enters command mode DCE enters command mode
&D2 Context deactivation Context deactivation
Table 7: PSD data mode
10.3.6î™–î™–î™–î™–Notes
• The ON/OFF DTR transition in direct link forces the DCE into command mode. In case of AT&D0 the DTR
transition is ignored, also in direct link.
• The escape sequence for the PSD data mode with a L2 protocol different from the PPP is not ~+++, and
it could be not supported. See the #unique_383/unique_383_Connect_42_t1 for more information.

Table of Contents

Other manuals for Ublox SARA-R4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ublox SARA-R4 Series and is the answer not in the manual?

Ublox SARA-R4 Series Specifications

General IconGeneral
BrandUblox
ModelSARA-R4 Series
CategoryControl Unit
LanguageEnglish

Related product manuals