Alternato
r
When repairing tractor by electric welding, all the conductors must be disconnected
alternator. Protect conductor '+B' against short circuit.
Alternator maintenance
When washing and cleaning the tractor protect the alternator from penetration of water or
diesel fuel! During operation the alternator must not be disconnected from the battery! The alternator
must never be put in operation without load, i.e. with the conductor disconnected from the '+B'
terminal and the '+D' terminal connected. Such a condition may induce an extremely high voltage
when the engine speed is increased, which would destroy the semiconductors! Never short-circuit
any alternator terminal during operation! The alternator must not be additionally excited. Such an
intervention would damage the semiconductors. Ensure perfect electric connection of the alternator
terminals and proper grounding of the alternator! Poles of the alternator may not be re-versed even
for a short time!
Electric installation overload
Charging is indicated by the red signal lamp on the united
board instrument which must be deactivated after the
start.
If the engine is running and the red signal lamp is
activated, it is a charging error. If this situation occurs,
stop the tractor and contact the service centre.
P18N004
Is signalized by the selected display changing to a display
with a symbol of a battery. It is a condition when electric
installation of the tractor has such take-off, that the
alternator performance is not sufficient to accumulator
charging. If this state occurs, turn off a device or increase
engine revolutions, load of electric installation drops and
originally selected display is displayed.
The operation of tractor in the electric
installation overload mode can lead to accumulator
depletion.
P18N005
ELECTRIC INSTALLATION
164

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zetor Proxima GP Series and is the answer not in the manual?

Zetor Proxima GP Series Specifications

General IconGeneral
BrandZetor
ModelProxima GP Series
CategoryTractor
LanguageEnglish

Related product manuals