Almost all the following works require certain experience and more exacting service and
diagnostic equipment. That's why we recommend to do the works at specialized or authorized
workshops.
Cogged belt tension
Bleeding of tractor brake system
With proper cogged belt tension the bending of belt must
be 5.5 mm with force effect of 25 N on a single belt.
Perform cogged belt tension to prescribed value after
releasing tightening screws (1, 2).
* Cogged belt tension of air-condition compressor
With proper cogged belt tension, bending of belt must be
7.5 mm with force effect of 25 N on a belt.
Perform cogged belt tension to prescribed value after
releasing tightening screws of air-condition compressor.
FH12N085
Carry out bleeding of the brake system of the tractor
always in the following order:
1. Pneumatic brake system for trailers.
2. Foot brakes of rear wheels.
3. Brake system of the front driving axle.
4. Hydraulic brakes of the trailer.
Carry out bleeding of the pneumatic brake system for
trailers and foot brakes of the rear wheels with
disconnected brake pedals, separately for each wheel.
Carry out bleeding of the brake system of the front driving
axle and hydraulic brakes of the trailer with coupled brake
pedals.
During bleeding watch level of the fluid in the expansion
tank to prevent suction of air.
Brake fluid in the entire brake system should be replaced
after two
y
ears.
G735a
When bleeding the pressure air system for
trailers and the rear wheel brakes, one pedal (1) must
be always depressed by 7,5
+0,5
mm -measured to the
main brake valve piston rod i.e. 3
+0,2
mm at the
adjusting screw (2) and the second pedal is used for
bleedin
g
. For keepin
g
the ri
g
ht distance, insert the flat
gauge of corresponding thickness, i.e. 3
+0,2
mm,
between the pedal (1) and the adjusting screw (2).
E757
ADJUSTMENT
185

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Zetor Proxima HS 120 and is the answer not in the manual?

Zetor Proxima HS 120 Specifications

General IconGeneral
Cylinders4
Displacement4.156 L
Hydraulic Pump Flow60 l/min
Hydraulic SystemOpen center
PTO Speed540/1000 RPM
Max Speed40 km/h
Engine Power117 HP
Transmission24F + 24R
PTO Power104 HP

Related product manuals