Diagmessages of module AxisMain
Multi axis servo system - AX8000 103
Version: 1.1
6.4 2381, Continuous over current (device output side)
Phase V
The drive software detected an overcurrent on the motor phases V.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
2381 9089
Class Type
Error Overcurrent error
Standard Reaction Reset
Torque off Execute Reset-Command (Fault reset).
Possible Causes Solutions
Short circuit in the motor cable. Check the motor cable
Short circuit in the motor winding. Check the motor winding with an high voltage test or
check the winding resistance.
Internal: 0x2381, Continuous over current (device output side) Phase V