EasyManuals Logo
Home>Beckhoff>Servo Drives>AX8000

Beckhoff AX8000 User Manual

Beckhoff AX8000
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
Diagmessages of module DeviceMain
Multi axis servo system - AX8000 83
Version: 1.1
4 Diagmessages of module DeviceMain
4.1 3210, DC link overvoltage
DC link overvoltage because the brake power of the power supply module is too low.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
3210 12816
Class Type
Error Overvoltage error
Standard Reaction Reset
Torque off Execute Reset-Command (Fault reset).
Possible Causes Solutions
Parameterization of the brake chopper from the
power supply module is wrong.
Check the parameterization of the brake chopper
from the power supply module.
The brake resistor from the power supply module is
defective
Measure the current resistance of the brake resistor.
Wrong selection of the brake resistor from the power
supply module.
Check the resistance of the brake resistor. Check the
power of the brake resistor.
Internal: 0x3210, DC link overvoltage

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beckhoff AX8000 and is the answer not in the manual?

Beckhoff AX8000 Specifications

General IconGeneral
BrandBeckhoff
ModelAX8000
CategoryServo Drives
LanguageEnglish

Related product manuals