Diagmessages of module AxisMain
Multi axis servo system - AX8000138
Version: 1.1
6.39 63A0, Motor or Primary Feedback changed
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
63A0 25504
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Extended Reset-Command (Fault reset with
'Unlock extended fault reset' Parameter).
Internal: 0x63A0, Motor or Primary Feedback changed