Diagmessages of module Interpolator
Multi axis servo system - AX8000 169
Version: 1.1
7.2 8680, Position Demand Value outside of the specified
Position Range Limits
Position Demand Value outside of the specified Position Range Limits
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
8680 34432
Class Type
Error Error
Standard Reaction Reset
Closed loop ramp Execute Reset-Command (Fault reset).
Possible Causes Solutions
Parameter Interpolator: To low NC-Task cycle time
for this interpolation sub mode select.
Adjust NC-Task cycle time.
Internal: 0x8680, Position Demand Value outside of the specified Position Range Limits