Diagmessages of module TorqueControl
Multi axis servo system - AX8000188
Version: 1.1
12.4 6320, Parameter error
The mentioned parameter contains a not accepted value.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
6320 25376
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
Something is wrong with the parameters in this
object.
Please check the parameters of the mentioned
object.
Internal: 0x6320, Parameter error in object 0x%x/%x