Diagmessages of module AxisMain
Multi axis servo system - AX8000 123
Version: 1.1
6.24 6391, Factor Group Parameters: Feed constant illegal
shaft revolutions
The actual combination of the factor group Parameters is not allowed for this Device.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
6391 25489
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
The feed constant - shaft revolutions contains an
illegal value (Object 0x6092/2 ChA or 0x6892/2 ChB).
Please set value to '1'.
Internal: 0x6391, Factor Group Parameters: Feed constant illegal shaft revolutions