Diagmessages of module SyncServoMotor
Multi axis servo system - AX8000 225
Version: 1.1
16.13 7185, Motor overtemperature shut down
The thermal sensor of the motor has detected an overtemperature and turned off
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
7185 29061
Class Type
Error Motor overtemperature shut down
Standard Reaction Reset
Closed loop ramp Execute Reset-Command (Fault reset).
Possible Causes Solutions
The thermal sensor of the motor has detected an
overtemperature and turned off
Reduced the motor temperature.
Internal: 0x7185, Motor overtemperature shut down