Diagmessages of module AxisDebug
Multi axis servo system - AX8000246
Version: 1.1
19 Diagmessages of module AxisDebug
19.1 FFFF, Internal Error,
Internal Error
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
FFFF 65535
Class Type
Error Error
Standard Reaction Reset
Closed loop ramp Execute Reset-Command (Fault reset).
Possible Causes Solutions
An unknown hard- or software error has occurred. Disconnect the power supply module from the mains
(including the 24 V power supply) and start a new
attempt. If this error occurs repeatedly, please call
the Beckhoff support that is responsible for you.
Internal: 0xFFFF, Internal Error, Additional Errorcode 0x%x