Diagmessages of module AxisMain
Multi axis servo system - AX8000114
Version: 1.1
6.15 5187, Power supply communication is not established
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
5187 20871
Class Type
Error Error
Standard Reaction Reset
Torque off Execute Reset-Command (Fault reset).
Possible Causes Solutions
The Power supply status is not alive. Please Check if the Power supply controlword of this
Axis Device is linked to the Power Supply Device and
the Device is in EtherCAT OP.
The Power supply SDO communications are not
finished.
Please Check if the Power supply communication
parameters and status of DeviceMain.
Internal: 0x5187, Power supply communication is not established