Diagmessages of module AxisMain
Multi axis servo system - AX8000 111
Version: 1.1
6.12 4310, Drive overtemperature shut down
The drive temperature has reached a critical value.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
4310 17168
Class Type
Error Drive overtemperature shut down
Standard Reaction Reset
Closed loop ramp Execute Reset-Command (Fault reset).
Possible Causes Solutions
The ambient temperature is too high Cool down the ambient temperature
The fan is defective Check the fan
Internal brake power and power loss of axis are too
high
Lower the brake power and power loss of axis
The cooling slots or the measuring sensors are
polluted
Clean the cooling slots and the measuring sensors
Internal: 0x4310, Drive overtemperature shut down