Diagmessages of module VelocityControl2
Multi axis servo system - AX8000178
Version: 1.1
10 Diagmessages of module VelocityControl2
10.1 3183, The bipolar velocity limit is higher than 1/4 of
position range limit per EtherCAT Sync1 cycle.
The maximum accepted position step per cycle is 1/4 of the position range limit range. This error occurs, if
the resulting velocity is lower than the bipolar velocity limit.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
3183 12675
Class Type
Error Error
Standard Reaction Reset
Closed loop ramp Execute Reset-Command (Fault reset).
Possible Causes Solutions
The maximum accepted position step per cycle is 1/4
of the position range limit range. This error occurs, if
the resulting velocity is lower than the bipolar velocity
limit.
Raise your position range limit or lower your bipolar
velocity limit.
Internal: 0x3183, The bipolar velocity limit is higher than 1/4 of position range limit per EtherCAT Sync1
cycle.