Diagmessages of module AxisMain
Multi axis servo system - AX8000126
Version: 1.1
6.27 6394, Factor Group Parameters: Position encoder
resolution illegal encoder increments
The actual combination of the factor group Parameters is not allowed for this Device.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
6394 25492
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
The position encoder resolution - encoder increments
contains an illegal value (Object 0x608F/1 ChA or
0x688F/1 ChB).
Please compare it to your encoder values.
Internal: 0x6394, Factor Group Parameters: Position encoder resolution illegal encoder increments