Diagmessages of module AxisMain
Multi axis servo system - AX8000148
Version: 1.1
6.49 63AA, Object changed in EtherCAT SafeOP or OP.
This errormessage was created, because this change during Runtime is potentially dangerous, if you don't
know what you do.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
63AA 25514
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
The value of the position range limit or a Factor group
object was changed in EtherCAT SafeOP or OP.
Execute fault reset command.
Internal: 0x63AA, Object 0x%X/%X changed in EtherCAT SafeOP or OP.