Standard-Messages
Multi axis servo system - AX800046
Version: 1.1
3.32 A000, Transition Pre-Op to Safe-Op not successful.
Sync Manager Length Error.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
A000 40960
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
The Parameters of the CoE Communication Objects
do not fit the Sync Manager Parameters.
Please check, if you are working with the right
EtherCAT Device Description XML-File.
Internal: 0xA000, Transition Pre-Op to Safe-Op not successful. Sync Manager %u Length Error. Requested
Length=0x%x is not between Min=0x%x and Max=0x%x