Standard-Messages
Multi axis servo system - AX800022
Version: 1.1
3.8 5585, Unexpected EEPROM
The Identity EEPROM of a Pcb is unexpected. This Device shouldn't contain this Pcb.
- ID 0: ControlPcb
- ID 1: FrontPcb
- ID 2: AdditionalAxisPcb
- ID 3: DisplayPcb
- ID 6: SafetyPcb
- ID 7: CpuPcb
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
5585 21893
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable A reset is not possible. The drive detected a fatal
hard- or software error.
Possible Causes Solutions
There is an internal hardware error. Send the AX8000 to the Beckhoff branch office that is
responsible for you.
Internal: 0x5585, Unexpected EEPROM Pcb ID %u.