Diagmessages of module AsynchronousMotor
Multi axis servo system - AX8000 243
Version: 1.1
18.14 7186, Commutation offset source: No commutation
offset existing in source 'encoder memory'
There is no commutation offset stored, for the selected source 'encoder memory'.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
7186 29062
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
A commutation offset should used, but no position
offset has been saved.
Calibrate the axis and save the new commutation
offset.
Internal: 0x7186, Commutation offset source: No commutation offset existing in source 'encoder memory'