Diagmessages of module AxisMain
Multi axis servo system - AX8000 135
Version: 1.1
6.36 639D, Acceleration factor illegal.
The actual combination of the factor group Parameters is not allowed for this Device.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
639D 25501
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
The acceleration factor (Object 0x6097 ChA or
0x6897 ChB) does not adjust the velocity scaling to 1
degree/s
2
in case of rotary Motors and 1 um/s
2
in
case of linear encoder.
Please change your setting to the suggested value.
Internal: 0x639D, Acceleration factor illegal. A possible Value would be %u/%u.