Diagmessages of module AxisMain
Multi axis servo system - AX8000 115
Version: 1.1
6.16 5441, Positive limit switch active
Positive limit switch reached
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
5441 21569
Class Type
Error Error
Standard Reaction Reset
Closed loop ramp Execute Reset-Command (Fault reset).
Possible Causes Solutions
The axis has been moved to the positive limit switch. Please move the axis away from the positive limit
switch.
Internal: 0x5441, Positive limit switch active