Page #129 background image
Diagmessages of module AxisMain
Multi axis servo system - AX8000 129
Version: 1.1
6.30 6397, additional Factor Group Parameters: Feed
constant illegal shaft revolutions
The actual combination of the factor group Parameters is not allowed for this Device.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
6397 25495
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
The additional feed constant - shaft revolutions
contains an illegal value (Object 0x60EE/1 ChA or
0x68EE/1 ChB).
Please set value to '1'.
Internal: 0x6397, additional Factor Group Parameters: Feed constant illegal shaft revolutions