Standard-Messages
Multi axis servo system - AX800016
Version: 1.1
3.2 5190, Test 5V supply failed
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
5190 20880
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable A reset is not possible. The drive detected a fatal
hard- or software error.
Possible Causes Solutions
There is an internal hardware error. Send the AX8000 to the Beckhoff branch office that is
responsible for you.
Internal: 0x5190, Test 5V supply failed