Diagmessages of module AxisMain
Multi axis servo system - AX8000 147
Version: 1.1
6.48 63A9, Position range limit Inc with remainder is not
supported for secondary feedback.
The position range limit is scaled internally to encoder increments. This calculation result contains a
remainder, which is not supported for the secondary feedback.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
63A9 25513
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
The position range limit is scaled internally to encoder
increments. This calculation result contains a
remainder, which is not supported for the secondary
feedback.
Please check the position range limit and the factor
group parameters of this feedback.
Internal: 0x63A9, Position range limit Inc with remainder is not supported for secondary feedback.