7.9.3.2 [Operating mode] [Pulse] - Quantity
The desired quantity per input pulse is entered in the Quantity setting mode. The pump
software then automatically calculates the required metering speed of the pump. Before
this, the value 0 must be selected in the configuration level under the menu item
[Pulse interval]
. This automatically switches from input type ‘Concentration’ to input type
‘Quantity’ .
Fig. 39: Operating mode: Pulse
1.
[Call up the main menu] :
Ä
Chapter 7.7 ‘Main menu’ on page 73
2. [Operating mode] - [Pulse]
.
3.
[Click Next]
to save the setting.
ð
Screen change for the setting: ‘Pulse interval
’.
4. DO NOT enter a pulse interval or set the pulse interval to 0!
For this, set 0 in the place before the decimal point using the scrollbar
.
Then select the field for entering the place after decimal point and set it likewise to 0
using the scrollbar.
5.
[ Click Next] to save the setting.
ð
Screen changes to the ‘pulse memory
’ query.
6. Select whether the ‘pulse memory
’ is to be used.
ð
If the ‘pulse memory’ has been selected, a
is set in the selection box.
7.
Press the button.
ð
Settings are saved, and the screen returns to the overview of the
[Operating mode] .
8.
Press the button.
ð
The screen switches back to the overview [Main menu] .
9.
Press the button.
ð
The screen switches back to the [operating display] .
10. Press and hold the displayed value (l/pulse) of the Quantity for approx. 3 seconds.
ð
The configuration page for changing the unit (l/pulse) is displayed
11. Slightly tap the desired unit (l/pulse, ml/pulse, g/pulse) of the Concentration setting
and select it.
12.
Press the button.
ð
The screen switches back to the concentration setting.
13. If necessary
, adjust the concentration value once again with the newly set unit.
14.
Press the button.
ð
The screen switches back to the [operating display] .
Control / Software
86417102276 Rev. 5-02.2020