14.3.4 Pump key group IV
"Packaging/accessories" [S|0]
Pos. 13: ‘Packaging’
0 No packaging
S Standard packaging
Pos. 14: ‘Accessories/other
0 No accessories
14.4 General data
Description
Type
00510X
Type
01
110S
Type
03003M
Type
05010M
Type
12003M
max. metering capacity [l/h]
1)
Metering mode
5 11 30 50 120
Metering mode
4,2 9,2 25 41,7 100
Metering mode
3,3 7,3 20 33,3 80
min. metering capacity [l/h] 0,05 0,11 0,30 0,50 1,2
max. metering back-pressure [MPa (bar)] 0,1 (10) 0,03 (3) 1 (10) 0,03 (3)
max. stroke frequency [1/min]
2)
Metering mode
171 160 162 164
Metering mode
143 133 135 137
Metering mode
114 107 108 109
Metering quantity per stroke [ml] 50 Hz/60 Hz
2)
0,53 1,04 3,16 5,74 13,51
Reproduction accuracy [%] < ± 3
max. conveyable viscosity
[mPas] with valves:
Default 200 100 200 100
Spring-loaded with
metering mode
500 250 500 250
Spring-loaded with
metering mode
1000 500 1000 500
Permissible ambient
temperature [°C]
3)
2 - 45
max. suction height [mWs]
3)
V
iscosity:
up to 50 mPas 2
over 50 mPas 1
max. suction line length [m]
V
iscosity:
up to 50 mPas 3
over 50 mPas 2
max. suction side pre-pressure [MPa (bar)] 0,2 (2) 0,1 (1) 0,2 (2) 0,1 (1)
min. differential pressure suction and pressure side
[MPa (bar)]
0,1 (1) 0,05 (0,5) 0,1 (1) 0,05 (0,5)
min. hose Ø [mm] suction side;
viscosity:
up to 50 mPas
4
5 6 12
over 50 mPas 9 12 19
min. hose Ø [mm] pressure
side; viscosity:
up to 50 mPas
5
5 6 9
over 50 mPas 6 9 12
Noise level (DBA) at a distance of 1 m
(according to DIN EN 12639/ EN ISO 9614-2)
< 60
Weight [kg] 3,1 3,8 5,2 5,7
Approvals CE
1) V
alues determined with water as the metering medium at a temperature of 20 °C.
2) Values vary depending on calibration.
3) Suction height determined with clean, moistened valves at maximum stroke frequency.
4) Measurement in the MK240 heating cabinet.
Technical specifications
184417102276 Rev. 5-02.2020