Page #41 background imageLoading...
Page #41 background image
Vital Signs Monitor User Manual Ward Round Mode
- 33 -
bed No. first name last name patient type the 1
st
patient info. item
23 Xiaoming Wang 1 12345
… …
Step 2: Save the file as CSV with comma delimiter format. The file name should be fixed as
‘ImportPatientList.csv’, and the encoding format of the file should be UTF-8.
NOTE:
1 In the patient list of CSV data file, first name, last name and the 1
st
patient info. item
cannot be more than 63 bits for each.
2 In importing process, the monitor will import the patient information that meets the
requirements, and the wrong patient information will be prompted. The wrong patient
information needs to be revised and re-imported.
If Network is selected and the monitor is connected with network server, user can set the query
conditions (Admission Date, Department), and click query icon to show the patients.
All patients to be imported will be listed in a new window. Choose patients you want and click
Import.
During importing, if the total patients in the monitor exceed upper limit (1000 patients), a
confirmation box will be popped up. Choose OK to enter Patient Management window, and
user should delete part of existing patients, then return to import patient window to import again.
Choose NO to return to Import Patient window, and user should delete part of patients who
need to be imported, then import again.
Refresh patient list
If monitor is connected with network server and ADT Query (in User Maintain) is also set to on,
click shortcut key
> icon to set query condition (such as Admission Date,
Department) > click query icon
to show the patients > click Refresh List , and then all
eligible patients will be refreshed to the window of Select Patient.
NOTE:
1 The operation of importing will keep “the patients those exist in the monitor but not
found in network”. However, the operation of refreshing will delete those patients.
2 During importing or refreshing, if the 1
st
patient information item or the bed No. has
conflict, the monitor will replace all conflicting patient information. But the patient
measurement status will keep unchanged as the previous patient for the conflict of
the 1
st
patient information item, and recover to the initial unmeasured status for the
conflict of bed No..
5.2.3 Delete Patient
Select Patient Management > Delete > choose patients who need to be deleted or directly select
Page or All > Delete.