179
8.1 Scanner Settings
8
SCANNER SETTINGS
■ Settings
Using the Software Operation Panel, you can configure the following settings for the scanner connected to
the PC.
[Device setting]
Item Explanation Selectable parameter Default
Page counter
(Consumables
counter)
For evaluating the consumable
replacement cycle or cleaning cycle.
Use this function to reset the counters
after replacing consumables or the
cleaning.
Refer to “5.1 Consumables and
Replacement Cycle” on page 124.
After Cleaning/Pad/Pick roller/Sepa-
rator Roller/Brake rollerremaining ink
level (only for the imprinter option)
-
Power saving Select the waiting time before entering
the Power saving mode.
Refer to “8.2 Power saving setting”
on page 185.
Setting range 15 to 55 minutes (set in
steps of 5 min.)
15 min.
Offset setting Adjust the start position for the docu-
ment scanning.
Refer to “8.3 Offset/Scan scale” on
page 186.
Left right: setting range -2 to 3mm
(set in 0.5mm steps)
Up down: setting range -2 to 3mm (set
in steps of 0.5mm)
left right
0mm
up down
0mm
Vertical magnifi-
cation Adjustment
Adjust the magnification in the feed-
ing direction.
Refer to “8.3 Offset/Scan scale” on
page 186.
Setting range -6.3% to 6.3% (set in
0.1% steps)
0%