EasyManuals Logo
Home>Fujitsu>Server>PRIMERGY RX1330 M5

Fujitsu PRIMERGY RX1330 M5 User Manual

Fujitsu PRIMERGY RX1330 M5
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #223 background imageLoading...
Page #223 background image
10.2.2 General memory population rules
–
Populate memory slot 1 / channel A (DIMM 1A) first.
–
Within all channels memory slot 1 must be populated prior to slot 2.
–
For maximum performance, populate both channels with the same amount
of memory (symmetric dual channel configuration).
–
If memory modules with dif
ferent capacities are used:
–
Install modules with higher capacities first.
– Within a channel, install modules in descending order of capacity.
–
If memory modules with different speeds are used, the lowest clock rate
applies for all DIMMs.
Channel A B
Slot ID 1A 2A 1B 2B
Dimm# 1 x
Dimm# 2 x x
Dimm# 3 x x x
Dimm# 4 x x x x
Table 3: Mounting order
10.3 Installing memory modules
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools: tool-less
Main memory
RX1330 M5 Upgrade and Maintenance Manual 223

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX1330 M5 and is the answer not in the manual?

Fujitsu PRIMERGY RX1330 M5 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX1330 M5
CategoryServer
LanguageEnglish

Related product manuals