13.3 Common operation panel (COP)
13.3.1 Replacing the COP
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Software: 5 minutes
Tools: Phillips PH1 / (+) No. 1 screw driver
Note on system information backup/restore
The COP contains the Chassis ID EPROM that contains system information
like server name and model, housing type, serial number and manufacturing
data. To avoid the loss of non-default settings when replacing the system
board, a backup copy of important system configuration data is automatically
stored from the system board NVRAM to the Chassis ID EPROM.
CAUTION
For that reason the COP and the system board must not be replaced
simultaneously! In this case, restoring the system configuration data on
the system board would fail.
â–¶
Reconfigure the BIOS/iRMC and restore the system information like
server name, server model, housing type, serial number and
manufacturing data manually by Chassis ID Prom T
ool.
Preliminary steps
â–¶
"Locating the defective server" on page 43
.
â–¶
If applicable, "Removing the front cover with lock" on page 45.
â–¶
"Shutting down the server" on page 46.
â–¶
"Disconnecting the power cord" on page 47.
â–¶
"Getting access to the component" on page 49.
â–¶
"Removing the air duct" on page 65.
Front panel
258 Upgrade and Maintenance Manual RX1330 M5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX1330 M5 and is the answer not in the manual?

Fujitsu PRIMERGY RX1330 M5 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX1330 M5
CategoryServer
LanguageEnglish

Related product manuals