If applicable, "Installing the front cover with lock" on page 61
.
7.5.7 Replacing the 4x 2.5-inch HDD backplane
(RX1330 M5S)
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools: tool-less
The 4x 2.5-inch HDD backplane is available in a SAS/SATA or NVMe
variant depending on the configuration.
Preliminary steps
â–¶
"Locating the defective server" on page 43
.
â–¶
If applicable, "Removing the front cover with lock" on page 45.
â–¶
"Shutting down the server" on page 46.
â–¶
"Disconnecting the power cord" on page 47.
â–¶
"Getting access to the component" on page 49.
â–¶
Release all HDD/SSD modules and pull them out a few centimeters, see
"Removing a 2.5-inch HDD/SSD module" on page 142.
CAUTION
The HDD/SSD modules need not to be removed.
â–¶
If you want to remove them nevertheless, check if all HDD/SSD
modules are uniquely identified so that you can reinsert them
into their original bays.
â–¶
Release all dummy modules and pull them out a few centimeters, see
"Removing a 2.5-inch HDD/SSD dummy module" on page
139
.
Hard disk drive (HDD) / solid state disk (SSD)
154 Upgrade and Maintenance Manual RX1330 M5

Table of Contents