Install the iRMC microSD card, see "Installing the iRMC microSD card" on
page 306.
▶
Install all fan modules, see "Installing the new fan module" on page 176
.
▶
If applicable, install all expansion cards, see "Installing an expansion card"
on page 195.
▶
Install all riser modules, see "Installing a riser module" on page 64.
▶
Install all memory modules, see "Installing a memory module" on page 224.
Ensure that you reinstall each memory module in the slot it was
located before the replacement.
▶
Install the air duct, see "Installing the air duct" on page
66.
▶
"Reassembling" on page
53.
▶
Install all PSUs, see "Installing a hot-plug PSU" on page 102.
▶
Connect all external cables.
▶
"Connecting the power cord" on page 57.
▶
"Switching on the server" on page 60.
▶
If applicable, "Installing the front cover with lock" on page 61.
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed.
This only indicates that the CPU configuration has been altered. There
is no technical problem.
Proceed as follows:
●
Restart your server.
●
As soon as the startup screen appears, press the
[F2] function key to
enter the BIOS.
●
If a password is assigned, enter the password and press [Enter].
●
Select the Exit menu.
●
Select Commit settings and Exit.
●
Verify that the Global Error indicator stops flashing.
System board and components
334 Upgrade and Maintenance Manual RX1330 M5