When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed.
This only indicates that the CPU configuration has been altered. There
is no technical problem.
Proceed as follows:
Restart your server.
As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
If a password is assigned, enter the password and press [Enter].
Select the Save & Exit menu.
Select Save Changes and Exit or Save Changes and Reset.
Verify that the Global Error indicator stops flashing.
"Enabling replaced components in the BIOS" on page
81
.
"Resuming BitLocker functionality" on page 86.
11.4 Replacing the heat sink
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver
Depending on ATD support, there are different heat sinks available.
Preliminary steps
"Locating the defective server" on page 43
.
If applicable, "Removing the front cover with lock" on page 45.
"Shutting down the server" on page 46.
Processor (CPU)
RX1330 M5 Upgrade and Maintenance Manual 241

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX1330 M5 and is the answer not in the manual?

Fujitsu PRIMERGY RX1330 M5 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX1330 M5
CategoryServer
LanguageEnglish

Related product manuals