Appendix A. Specifications and Model Configurations
94 PanaFlow™ LC User’s Manual
• CRR 0.5, 1.0, and 2.0 MHz
• CAT 0.5, 1.0, and 2.0 MHz
Process Fluid Temperature Range
Local mount: -40°F to 185°F (-40°C to 85°C)
A.2 Electronics
Enclosures
Powder coated aluminum or stainless steel (SS316)
Classifications
US/CAN: Class I, Division 1,
Groups B, C, D; Class I, Zone 1, Ex
d IIB+H2 T6...150C;
ATEX/IECEx: Ex d IIB+H2 T6...150C
FISCO outputs Ta = -40°C to +60°C,
Type 4X
SINGLE SEAL
Electronics Mounting
Local or remote mounting Paths Three paths
Display
English
128 x 64 mono-color LCD display, configurable for single or dual measurement parameters
Keypad
Built-in magnetic, six-button, lockable keypad
Standard Inputs/Outputs
One 4 to 20 mA isolated output, 600-ohm maximum load
One additional output, may be configured as either a pulse or frequency
Additonal Inputs/Outputs
Two 4 to 20 mA isolated output, 600-ohm maximum load
Two 4 to 20 mA isolated input or RTD sensor input (Supports PT100: 3 and 4 Wire, PT1000: 3 and 4 Wire)
Digital Interfaces
Standard: RS485/Modbus® Optional: HART® 7.0 protocol, with 4 dynamic variables, includes one additional
4 to 20 mA analog output NAMUR NE43
Optional: Foundation Fieldbus® FISCO, LAS capable NAMUR NE107 with 5 AI blocks and a PID block