August 2003
7-16 Logging Data
Stopping (Pausing) a Log
To stop a log that is currently pending or running,
1. First, select the log you wish to pause in the Log Manager
(shown in Figure 7-2 on page 7-4).
2. Then open the Log Menu, scroll to the Pause option, and press
[ENTER].
The PM880 returns to the Log Manager, which displays the
highlighted log with “Paused” in the State line.
Restarting a Log
To restart a paused log:
1. First, select the log you wish to restart in the Log Manager
(shown in Figure 7-2 on page 7-4).
2. Then open the Log Menu, scroll to the Start option, and press
[ENTER].
The PM880 returns to the Log Manager, which displays the
highlighted log with a status of “Pending” or “Running.”
Ending a Log
To end a log:
1. First, select the log you wish to end in the Log Manager
(shown in Figure 7-2 on page 7-4).
2. Then open the Log Menu, scroll to the End option, and press
[ENTER].
The PM880 returns to the Log Manager, which displays the
highlighted log with a status of “Finished.” The space not used
by the finished log is freed for reuse.
Note: You cannot restart a finished log. You must create a new
log with the same parameters.

Table of Contents

Other manuals for GE PM880

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE PM880 and is the answer not in the manual?

GE PM880 Specifications

General IconGeneral
BrandGE
ModelPM880
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals