ADV200 • Functions description and parameters list 111
22 – FUNCTIONS
22.1 – FUNCTIONS/SPEED RATIO
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
22.1.1 3000 Dig speed ratio perc INT16 16/32 100 CALCI CALCI ERW FVS
This function allows a congurable speed ratio (Speed ratio) to be applied to the main reference and deter-
mines the speed ratio percentage. This setting can be performed in digital form, via eldbus, or through an
analog input. This function is useful in “multi drive” systems where a slip value is required between the vari-
ous motors being used. The resulting speed value can be read through the Speed ratio mon parameter on a
programmable analog output.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
22.1.2 3002 Speed ratio src LINK 16/32 3000 0 16384 ERW FVS
Selection of the origin (source) of the signal that determines the speed ratio percentage value. The terminal to
be associated with this function can be selected from the “L_VREF” selection list.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
22.1.3 3008 Speed ratio div ENUM 1 1 1000 ERW FVS
This parameter denes the number of decimal positions for setting PAR 3000 Dig speed ratio. Possible values
are shown in the table below:
Speed ratio divider Values that can be set in
PAR 3000 Dig speed ratio
Corresponding % value
1 0-200 0-200
10 0-2000 0-200.0
100 0-20000 0-200.00
1000 0-32000 0-32.000
1 1
10 10
100 100
1000 1000
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
22.1.4 3010 Speed ratio mon FLOAT INT16 0 0 0 ER FVS
The speed ratio value to apply to the selected speed reference signal value is displayed.