154 ADV200 • Functions description and parameters list
22.19 - FUNCTIONS/TIMERS
Menu for managing two programmable and independent Timer modules in order to delay the effect of the digital inputs
and of all of the parameters on the L_DIGSEL1 selection list.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
22.19.1 3550 Timer1 src LINK 32BIT 6000 0 16384 ERW FVS
22.19.5 3560 Timer2 src LINK 32BIT 6000 0 16384 ERW FVS
Lets you assign the control signal to be delayed at Timer X function block input. The signals that can be used
for this function can be set from the ones on the L_DIGSEL1 selection list.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
22.19.2 3552 Timer1 pos delay s FLOAT 0.10 0.0 30.0 ERW FVS
22.19.6 3562 Timer2 pos delay s FLOAT 0.10 0.0 30.0 ERW FVS
Setting of positive delay edge.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
22.19.3 3554 Timer1 neg delay s FLOAT 0.10 0.0 30.0 ERW FVS
22.19.7 3564 Timer2 neg delay s FLOAT 0.10 0.0 30.0 ERW FVS
Setting of negative delay edge.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
22.19.4 3556 Timer1 mon INT32 0 0 0 ER FVS
22.19.8 3566 Timer2 mon INT32 0 0 0 ER FVS
Display of Timer output state.

Table of Contents

Other manuals for gefran ADV200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran ADV200 and is the answer not in the manual?

gefran ADV200 Specifications

General IconGeneral
Brandgefran
ModelADV200
CategoryInverter
LanguageEnglish

Related product manuals