ADV200 • Functions description and parameters list 5
A – Programming
A.1 Menu display modes
The programming menu can be displayed in two modes, which can be selected using the Access mode pa-
rameter (04 - DRIVE CONFIG menu):
Easy (default) only the main parameters are displayed.
Expert all the parameters are displayed
A.2 Programming of “function block” analog and digital input signals
The signals, variables and parameters of each single “function block” of the drive are interconnected in order to
achieve the congurations and controls inside the control system.
These can be managed and modied using the keypad, PC congurator or eldbus programming.
The programming mode is based on the following logic:
Src (source; i.e.: Ramp ref 1 src, PAR: 610)
This term denes the source of the function block input, i.e. the signal to be processed in the
function block.
The different congurations are dened in the relative selection lists
.
cfg (conguration; i.e.: Mpot init cfg, PAR: 880)
This term refers to the parameter setting and its effect on the function block.
For example: Ramp times, internal reference adjustment, etc...
mon (display; i.e.: Ramp ref 1 mon, PAR: 620)
This term refers to the variable output from the function block, which is the result of the
calculations performed on the actual block
.
Input selected
Parameter
Parameter
Parameter
Variable
Cfg
src Monitor
Function block
A.3 Variable interconnections mode
The source (src) allows the desired control signal to be assigned to the function block input.
This operation is performed by using specic selection lists.
Possible control signal sources:
1 – Physical terminal
The analog and digital signals come from the terminal strip of the regulation card and/or from those of the
expansion cards.
2 – Drive internal variables
Internal drive control system variables, from “function block” calculations, sent via keypad, PC congurator or
eldbus.

Table of Contents

Other manuals for gefran ADV200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran ADV200 and is the answer not in the manual?

gefran ADV200 Specifications

General IconGeneral
Brandgefran
ModelADV200
CategoryInverter
LanguageEnglish

Related product manuals