416 11 Test run and Program Run
11.7 Optional Program Run Interruption
11.7 Optional Program Run
Interruption
Function
The TNC optionally interrupts the program or test run at blocks
containing M01. If you use M01 in the Program Run mode, the TNC
does not switch off the spindle or coolant.
U Do not interrupt program run or test run at blocks
containing M01: Set soft key to OFF
U Interrupt program run or test run at blocks containing
M01: Set soft key to ON