HEIDENHAIN TNC 426, TNC 430 423
12.4 Setting the Data Interfaces
Assign
This function sets the destination for the transferred data.
Applications:
n Transferring values with Q parameter function FN15
n Transferring values with Q parameter function FN16
n Path on the TNC’s hard disk in which the digitized data are stored
The TNC mode of operation determines whether the PRINT or PRINT
TEST function is used:
You can set PRINT and PRINT TEST as follows:
File names
TNC mode of operation Transfer function
Program Run, Single Block PRINT
Program Run, Full Sequence PRINT
Test run PRINT TEST
Function Path
Output data via RS-232 RS232:\....
Output data via RS-422 RS422:\....
Save data to the TNC’s hard disk TNC:\....
Save data in directory in which the program with
FN15/FN16 or the program with the digitizing
cycles is located
- vacant -
Data Operating mode File name
Surface data Program run Defined in the
RANGE cycle
Values with FN15 Program run %FN15RUN.A
Values with FN15 Test run %FN15SIM.A
Values with FN16 Program run %FN16RUN.A
Values with FN16 Test run %FN16SIM.A