APPENDIX
B
PX4i and PX6i High Performance Printer User Guide 127
DEFAULT SETTINGS
Default Configuration
The following tables list the default values of the configuration commands sup-
ported on the printer. If you restore the printer to factory default settings, the
printer uses these values.
The commands are grouped by function and reflect the organization of the IPL and
Fingerprint setup menus. For detailed information on most of the commands, see
the Fingerprint Command Reference Manual or the IPL Command Reference Man-
ual.
Fingerprint Default Configuration
Ser-Com “uart1:” Parameters
Parameter Default Value
Baud rate 9600
Character length 8
Parity None
Stop bits 1
Flow control
RTS/CTS
ENQ/ACK
XON/XOFF; data to host
XON/XOFF; data from host
Disable
Disable
Disable
Disable
New line CR/LF
Receive buffer 1024 bytes
Transmit butter 1024 bytes