5.9 Replacing a Fan Module and PSU
This topic describes how to replace a fan module and power supply unit (PSU).
5.9.1 Removing a Fan Module
This topic describes how to remove a fan module.
Scenarios
Remove a fan module if it has failed.
Prerequisites
Conditions
None
Data
You have obtained the cabinet number and chassis number of the RH8100 V3.
You have located the RH8100 V3 based on the preceding information, and
labeled its panel to prevent misoperations.
You have determined the position on the RH8100 V3 for removing a fan
module.
Tools
ESD gloves
Packaging materials, for example, an ESD bag
Procedure
Step 1 Wear an ESD wrist strap or ESD gloves. For details, see 1 Safety Instructions.
Step 2 Press and hold down the plastic latch on the inner side of the fan module handle.
See step (1) in Figure 5-129.
Step 3 Pull the fan module out of the chassis in the arrow direction. See step (2) in
Figure 5-129.
RH8100 V3 Server
User Guide 5 Removing and Installing Parts of the RH8100 V3
Issue 30 (2019-12-19) Copyright © Huawei Technologies Co., Ltd. 251