Figure 5-8 Installing a CPU protective cover
----End
5.2.6 Installing a CPU
This topic describes how to install a CPU.
When E7 v2/v3 CPUs are congured, use HFCs whose BOM number is 03022JBN.
When E7 v4 CPUs are
congured, use HFCs whose BOM number is 03023URP.
When replacing CPUs of dierent platforms, ensure that new CPUs are compatible with
other components of the server. For details, use the Intelligent Computing
Compatibility Checker.
Scenarios
NO TICE
Only the personnel authorized by Huawei and Huawei technical support
personnel can install a CPU in Huawei servers.
Do not wear ESD gloves during CPU replacement. The gloves may catch on pins
on the CPU socket and damage it.
Install a CPU if:
A CPU has failed.
A CPU needs to be replaced with a new model.
Prerequisites
Conditions
You have powered o the RH8100 V3. For details, see 6.2 Powering O the
RH8100 V3. Then you have removed all power cables from the server.
RH8100 V3 Server
User Guide 5 Removing and Installing Parts of the RH8100 V3
Issue 30 (2019-12-19) Copyright © Huawei Technologies Co., Ltd. 120