EasyManuals Logo
Home>IBM>Server>S85 pSeries 680

IBM S85 pSeries 680 User Manual

IBM S85 pSeries 680
691 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #237 background imageLoading...
Page #237 background image
Reference
Code
Description/Action
(Perform all actions before exchanging Failing
Items)
Failing Item
CE19 Regulator not present.
If regulator 3 in slot 16 is installed, exchange the
failing items.
1. Go to MAP 1520: Power on page 88.
2. ac box
Location: U1.2-V7
Note: If the SPCN network is cabled as specified in Cabling the System Rack and I/O
Rack on page 31, then the SPCN rack addresses are assigned as 1 to the
system rack, 2 to the primary I/O drawer (drawer that contains the service
processor), 3 to the next I/O drawer in the chain, and so on. This can be read as
the third character in the SRC. The fourth character in the SRC is the unit
address. The primary I/O drawer has a unit address of C. All other drawers have
a unit address of 1.
1xxx
Chapter 5. Error Code to FRU Index 215

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM S85 pSeries 680 and is the answer not in the manual?

IBM S85 pSeries 680 Specifications

General IconGeneral
BrandIBM
ModelS85 pSeries 680
CategoryServer
LanguageEnglish

Related product manuals