Function 08 - Fast Power Off
Use this function when the system is suspended and a power down cannot be
performed.
Initially, an attention SRC (11-x A1xx 8008) displays indicating that Function 08 has
been selected.
Note: If the server has Unattended Start Mode (USM) enabled, selecting this function
causes the server to power off and then power on again.
Functions 09 to 10 - Reserved
These functions are reserved for future operator panel operations.
Functions 11 to 19 - System Reference Code
Functions 11 through 19, if enabled, represent the words of the SRC.
Note: Function 11 provides the primary SRC. Function 12 is an informational status
message only and not used. Function 13 provides status information for service
support use. Functions 14 and 15 provide secondary reference codes in addition
to the primary SRC. Function 19 provides CCIN information for FRU
replacement.
Press Enter to view the SRC. If no SRC is present, press Enter to continue to the next
function.
Record the SRC information for error reporting. For example, the system processor
detected a failure.
1. Look at the four rightmost characters of the operator panel display for function 11.
These four characters are the unit reference code.
2. Look at functions 14 and 15 for more reference codes. Each is four characters in
length. There may be from zero to four unit reference codes contained in these
words. For example:
Word 11 - B455 rrrr
Word 14 - rrrr rrrr
Word 15 - rrrr 0000
Word 19 - CCIN CCIN
This example shows a total of four reference codes for this failure. The rrrr
signifies the reference codes. Each reference code has only one FRU associated
with it. The CCIN code is used to determine a failing FRU in some cases.
3. Find the unit reference code in the SRC tables.
Note: Depending on the source of the SRC, some functions do not report any SRC
status. All SRCs start with information in Function 11.
For more information on interpreting SRCs, refer to “Chapter 2. Introduction to
Diagnostics” on page 73 and “Unit Reference Codes” on page 185.
Appendix C. Operator Panel Function Codes 603