1. See “Noise Emission Notes” on page 71 for definitions of noise emission positions.
2. Noise emissions data for models S80 and S85 system is based on a system with the doors
closed.
3. Inrush currents occur only at initial application of power, no inrush occurs during normal
power off-on cycle.
4. The upper limit of the dry bulb temperature must be derated 1 degree C per 137M (450 ft.)
above 1295M (4250 ft.)
5. The upper limit of the wet bulb temperature must be derated 1 degree C per 274M (882 ft.)
elevation above 1370M (4500 ft.)
6. The use of the PCI SSA Multi-Initiater/RAID EL in the models S80 and S85 10 EIA I/O
Drawer limits the system usage to a 28°C(82°F) environment maximum.
Models S80 and S85 I/O Rack
Dimensions
Height
Width
Depth
1577 mm
650 mm
1019 mm
62.0 in.
25.5 in.
40.1 in.
Weight
1
(Base Rack) 159 kg 349 lbs.
Electrical (see specifications for drawers or enclosures)
Temperature Range (see specifications for drawers or enclosures)
Humidity Requirements (see specifications for drawers or enclosures)
Noise Emissions (see specifications for drawers or enclosures)
Clearances
Install/Air Flow
Service
Maintenance of a proper service clearance should allow proper air flow.
See “System Service Clearances” on page 70.
1. Configuration dependent, base weight plus weight of drawers.
68 Service Guide