ProtecTIER Service Menu running on rasap1
ProtecTIER Configuration (...)
----------------------------------------------------------------------
1) Configure ProtecTIER node
2) Recover Configuration for a replaced server
3) Configure RAS
4) Update Time, Date, Timezone & Timeserver(s)
5) Configure replication (...)
6) IP Network configuration (...)
7) Update Firmware
8) Update the System’s name
9) Validate configuration
B) Back
E) Exit
----------------------------------------------------------------------
>>> Your choice?
c. Type the numeral corresponding to Validate configuration and press
Enter. The following messages are displayed:
Testing fence ports [ Done ]
Validation is about to execute a fence on 1 node in the cluster, the
node will be forcefully shutdown and rebooted
To Continue please type "fence test", or "q" to quit:
4. Type fence test and press Enter.
The following messages are displayed.
Testing connectivity to the fence device [ Done ]
Would you like to stop the VTFD service on both nodes? (yes|no)
5. Type yes and press Enter.
The following message is displayed
Stopping VTFD locally[-]
6. After VTFD is stopped and the test finishes on Node A, disconnect the
keyboard and monitor from Node A and connect them to Node B.
7. Log in to Node B with the user name root and password admin.
8. Repeat Steps 3 on page 123 through 5 on Node B.
Note: Alerts might be generated as the validation tests are running. The
ProtecTIER Manager Alerts Log allows you to monitor the alerts as they occur.
To do so, on the ProtecTIER Manager workstation, click Alerts in the lower
right corner of the ProtecTIER Manager screen. The Alerts Log opens. See
Figure 55.
When you are finished reviewing alerts, click Clear Alerts in the lower-right
corner of the Alerts Log screen.
ts760101
Figure 55. Alerts Log
124 IBM System Storage TS7650 ProtecTIER Deduplication Appliance: Installation Roadmap Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS7650 and is the answer not in the manual?

IBM TS7650 Specifications

General IconGeneral
BrandIBM
ModelTS7650
CategoryStorage
LanguageEnglish

Related product manuals