Page #121 background image
114
15
MAINTENANCE
New2001
15
Scan does not operate.
The function display shows
erroneous information.
Data communication can-
not be made properly
The squelch is open.
Only 1 memory channel is programmed or other
channels are set as skip channels.
Priority watch is activated.
The CPU is malfunctioning.
Ethernet cable has a poor connection.
Set the squelch to the threshold point.
Program other memory channels or cancel the
memory skip function in the desired channels.
Cancel the watch.
Reset the CPU.
Re-connect the Ethernet cable.
Replace the Ethernet cable.
Fuse replacement
If the fuse blows or the transceiver stops functioning, nd the
source of the problem if possible, and replace the damaged
fuse with a new, rated one (FGB 15 A) as shown at right.
The DC power cable has 2 fuses, one each for positive (+;
red) and negative (; black) line.
15 A
fuse
PROBLEM POSSIBLE CAUSE SOLUTION REF.
p. 33
pgs. 74
to 76
pgs. 90,
91
p. 112
p. 17
ID-1_ENG_2.qxd 04.9.22 9:30 Page 114 (1,1)